Author Archives: MS Chaudhry

About MS Chaudhry

Writer is working in the field of construction since 25 years. Having vast experience and knowledge about electromechanical systems at different levels.

Method Statement For Installation Testing and Commissioning Of MATV Distribution System

This electrical method statement covers the installation, testing and commissioning procedure for the master antenna or MATV Distribution system. All the materials will be as approval from the consultant engineer and installation & routing will be as per the shop drawings approvals for MATV system. Minimum tools and  equipment’s for the installation and testing of… Read More: Method Statement For Installation Testing and Commissioning Of MATV Distribution… »

Overhead Power Transmission Line Route Selection Considerations

This article is very helpful for electrical engineers working on overhead power line design and any kind of transmission line related business. Overhead transmission lines play very vital role in our lives because if transmission of energy is not efficient it results power disruptions and losses of power itself. Below are some of the important… Read More: Overhead Power Transmission Line Route Selection Considerations »

Binary, Hexadecimal, Octal, and BCD Numbers

After reading this article, you shall be able to: Convert between binary and decimal numbers. Convert between decimal and binary fractions. Convert between binary and hexadecimal numbers. Convert between decimal and hexadecimal numbers. Convert between binary and octal numbers. Convert between binary and BCD numbers. The decimal number system is fine for calculations done by… Read More: Binary, Hexadecimal, Octal, and BCD Numbers »

Switchgear Panels Energization and De-Energization Procedure – Electrical Services Commissioning

This document covers the livening up and isolation of electrical supplies from the incoming power supply to the final circuit. The aim is to have a safe procedure for the livening up electrical supplies during the commissioning period and a safe procedure for isolating electrical supplies where remedial works are required due to defects found… Read More: Switchgear Panels Energization and De-Energization Procedure – Electrical Services Commissioning »

Hexadecimal Number System

The one main disadvantage of binary numbers is that the binary string equivalent of a large decimal base-10 number can be quite long. When working with large digital systems, such as computers, it is common to find binary numbers consisting of 8, 16 and even 32 digits which makes it difficult to both read and… Read More: Hexadecimal Number System »

Electrical Switchgear Installation Procedure – Medium Voltage MV Panel

This page provides steps for successful installation of medium voltage electrical switchgear panel on a construction project or building. The method of statement describes the procedure for material delivery inspection, installation and inspection of MV switch gears. Project Manager is the overall responsible person for the process of implementation of the work methods. The Construction… Read More: Electrical Switchgear Installation Procedure – Medium Voltage MV Panel »