Medium Voltage Indoor Dry Type Transformers Rating, Rated Voltage, Frequency and Ratio

The rated voltage ratio of the transformers at no load normally is specified at 50 Hz, this being related to the principal tapping of the transformer. Tapping shall be provided on the primary winding to provide a ratio variation of +7.5% and –2.5% in steps of 2.5%. The tap charge mechanism is of the off load… Read More: Medium Voltage Indoor Dry Type Transformers Rating, Rated Voltage, Frequency… »

How To Measure Transformer Winding Resistance

Transformer winding resistance is very important factor for the life of any transformer, this test is part of type tests, routine tests and field tests. The purpose of winding resistance test is to determine the following: Calculation of the I2R losses in transformer. Calculation of winding temperature at the end of temperature rise test of transformer. As a benchmark… Read More: How To Measure Transformer Winding Resistance »

Typical Limiting Values of Electrical Substation Equipments

On this page you can find permissible limits for different equipment’s which are part of a power distribution electrical substation. Also where available reference to the international standard is also available in last column. Typical values are provided for transformers, reactors, circuit beakers, current transformers, capacitors, isolators, surge arrestors, batteries and other miscellaneous equipment’s. 1.… Read More: Typical Limiting Values of Electrical Substation Equipments »

Cable Tray Ladder Trunking Wire Basket Installation Guidelines

What Are Cable Trays? An assembly of units/sections with associated fittings that form a rigid structural system to securely fasten or support cables. Think of a roadway bridge that supports traffic. Cable Tray Systems must provide protection to life & property against faults caused by electrical disturbances Lighting and failures which are part of the… Read More: Cable Tray Ladder Trunking Wire Basket Installation Guidelines »

Method Statement for Installation of Isolated Power Supply IPS Units

Below is given a brief method statement for Installation of Isolated Power Supply units or also called IPS Units. Pre installation requirements before commencing the installation work at site are: Operative to attend any site induction provided by the client. Check the  power  cables  and  earth  cable  sizes  are  done  as  per  approved drawings. Conduits,… Read More: Method Statement for Installation of Isolated Power Supply IPS Units »

Capacitor Bank Installation Method Statement

Installation of capacitor bank shall be carried out in accordance to project specifications and approved drawings and technical submittals etc. Installation will be carried out by skilled and suitably experienced electricians under supervision of highly competent site supervisors and engineers to ensure the correctness and quality of the work. Prior to dispatch of capacitor bank… Read More: Capacitor Bank Installation Method Statement »